How Tabulation Metrics Are Calculated

 Shared Tabulation Explanation

 

Metric

Formul

a

Notes

Acreage

Site area within the property line

Denominator for FAR and DU/AC

FAR (Floor Area Ratio)

Gross SF ÷ Site Area

TestFit's headline density metric

Efficiency (EFF%)

NRSF ÷ Gross SF

Also read as the gross-to-net ratio

NRSF / NRM

Total Unit Area + Balcony (only if balconies are toggled on)

Net rentable area

COMMON

Corridor area, including the run-up to stairs/lifts

 

STAIR

Staircase area

 

LIFTS

Elevator area

 

AMENITY

Area assigned to amenity spaces

Default designation for amenity program

BOH (Back of House)

Reserved area category

Documented by TestFit as "not yet implemented" — currently always zero

UNALLOCATED

Gross area that isn't NRSF, Common, Stair, Lifts, or Amenity

Space the solver couldn't assign to a category — see Caveats

Gross Conditioned SF

NRSF + COMMON + STAIR + LIFTS + AMENITY + BOH

All conditioned (air-conditioned) building area

EXTERNAL

Garage Gross Area + Balcony Area

 

GROSS SF

Gross Conditioned SF + EXTERNAL

The numerator TestFit uses for FAR

DU/AC (DU/HA)

Total Dwelling Units ÷ Site Acreage (or Hectares)

 

AVG (unit size)

Gross Conditioned SF of units ÷ Unit Count

 

AVG (parking)

Total Garage Area ÷ Total Stalls

 

Parking Ratio

Total Stalls ÷ Total Units

 

Bldg CVG% / Imp CVG%

Building Footprint (or Impervious Area) ÷ Site Area

Coverage percentages


Data Center Tabulation

Parameter

Definition

How it's derived

Electrical Availability (MVA)

Mega-Volt-Amps available to use on site

Entered directly as a site input, reflecting utility/interconnect capacity

Electric Efficiency

Usable MVA from the site

The share of nameplate MVA that's actually usable capacity

(MW) Power Per Bay

Available power allocated to each bay

One of two ways to define IT power (see below) — the "Use Per-Bay Power" method

Target Power Density

MW (or kW) of IT power per unit of Data Hall area

The alternate way to define IT power; a rate applied across Data Hall area

Design PUE (Power Usage Effectiveness)

Total Facility Power ÷ Critical (IT) Power

Set by the designer; TestFit uses it to back into non-IT power

Critical (IT) Power

Power delivered to compute equipment

= Power Per Bay × bay count, or Target Power Density × Data Hall area, depending on method

Non-IT (overhead) Power

Power spent on cooling, electrical losses, and other facility overhead

= Total Facility Power − Critical Power, where Total Facility Power = Design PUE × Critical Power